All Guides
Medium30-45 min
Testing and Replacing a Clothes Dryer Thermal Fuse
Fix a dryer that spins and tumbles but blows only cold air. Follow these step-by-step instructions to troubleshoot and complete the fix safely.
Safety Warning
UNPLUG 240V DRYER PLUG before removing rear metal cover.
Tools Needed
- Multimeter
- Nut driver
Materials Needed
- Replacement thermal fuse
Step-by-Step Instructions
1
Unplug Dryer & Pull from Wall
Disconnect power and disconnect flexible aluminum vent duct.
2
Remove Back Metal Panel
Unscrew 5/16-inch hex screws around perimeter.
3
Locate White Thermal Fuse
Find small white plastic component mounted on the blower housing.
4
Test Continuity with Multimeter
Touch probes to terminals. If 0 ohms continuity, fuse is good; if infinity (OL), fuse is blown.
5
Install Exact OEM Fuse
Screw new fuse in place, reconnect wires, and clean all lint from blower wheel.
When to Call a Professional
- A repeatedly blowing fuse indicates a dangerously clogged exterior dryer vent duct.
DIY Cost
$10 - $20
Professional Cost
$150 – $450+
Related Guides
Still Need Help?
Get an AI-powered diagnosis of your problem and connect with independent local professionals.
Get AI Diagnosis