How to Clean a Dirty Furnace Flame Sensor
Fix a furnace that ignites for 3 seconds and then immediately shuts down. Follow these step-by-step instructions to troubleshoot and complete the fix safely.
Safety Warning
Turn off power switch on the side of the furnace before removing the burner access door.
Tools Needed
- 1/4-inch nut driver or wrench
- Flashlight
Materials Needed
- Fine emery cloth or steel wool (0000 grade)
- Clean cloth
Step-by-Step Instructions
Turn Off Furnace Power
Flip the electrical switch mounted on or near the furnace.
Remove Burner Access Door
Lift or unhook the upper front metal panel of the furnace to expose the burner assembly.
Locate the Flame Sensor
Find the thin metal rod extending into the path of the last burner nozzle (opposite side of the spark/hot surface igniter).
Unscrew Mounting Hex Bolt
Use a 1/4-inch nut driver to remove the single screw holding the ceramic base of the sensor to the burner bracket.
Gently Polish Metal Rod
Rub the metal rod with fine steel wool or emery cloth to buff away invisible microscopic oxidation and carbon buildup.
Reinstall & Test Ignition
Screw sensor back in securely, replace the door firmly (door safety switch must engage), and turn power back on.
When to Call a Professional
- If the furnace still shuts off after cleaning, or the igniter does not glow orange, the control board or hot surface igniter is defective.
DIY Cost
$0 - $5
Professional Cost
$150 – $450+